Skip to main content

Table 4 Sensitivity, specificity, predictive value, and diagnostic accuracy of both needles in non-malignant cases

From: Endobronchial ultrasound guided Echo Tip Ultra HD 22G needle versus Echo Tip Pro Core HD 22G needle in diagnosis of mediastinal lesions

In non-malignant cases

Final diagnosis

Total

True +ve

True −ve

Echo Tip Ultra HD needle

+ve

4

0

4

–ve

9

1

10

 Total

13

1

14

Echo Tip ProCore HD needle

+ve

4

0

4

−ve

9

1

10

 Total

13

1

14

In non-malignant cases

Echo Tip Ultra HD needle diagnosis

Total

Yes

No

Echo Tip ProCore HD needle diagnosis

+ve

3

2

5

−ve

2

7

9

 Total

5

9

14

p value

0.9102

  1. Echo Tip Ultra HD and Echo Tip ProCore HD needles: sensitivity (%), 30.76%; specificity (%), 100%; positive predictive value (PV+) (%), 100%; negative predictive value (PV−) (%), 10%; false negative rate (%), 69.23%; diagnostic accuracy (%), 35.71%