Skip to main content

Table 3 Pulmonary function tests (PFT) of flour mills workers, Assiut

From: Assessment of respiratory health status of workers in flour mills of Assiut

PFT Parameters

No. (n = 184)*

Mean ± S.D. (range)

FVC%

87.89 ± 12.78 (52 – 120)

FEV1%

84.25 ± 14.94 (29 – 116)

FEV1/FVC

80.05 ± 10.25 (43 – 100)

FEF25%-75%

73.88 ± 23.43 (16 – 128)

PFT disorders

No

%

 Normal

117

63.6

 Restriction

18

9.8

 Obstruction

17

9.2

 Mixed

15

8.2

 Small airway disease (SAD)

17

9.2