Patient-ventilator asynchrony as a predictor of weaning failure in mechanically ventilated COPD patients

Abstract

Background

Patient-ventilator asynchrony is a common problem in mechanically ventilated patients. It is associated with adverse effects including increased work of breathing, patient discomfort, increased need for sedation, prolonged mechanical ventilation, weaning difficulties, and weaning failure. The purpose of the present was to describe patient-ventilator asynchrony and its impact on weaning outcomes in mechanically ventilated chronic obstructive pulmonary disease (COPD) patients.

Results

One hundred mechanically ventilated COPD patients were enrolled in this prospective study. Weaning failure (need of NIV or reintubation within 48 h) was noticed in 27 (27%) patients while 73 (73%) patients had successful weaning. Patients with failed weaning had significantly higher asynchrony index (A.I) and ineffective trigger index (ITI) in comparison with those with successful weaning (7.69 ± 3.71, 3.46 ± 2.59 versus 6.27 ± 3.14, 2.47 ± 2.08, respectively; P value< 0.04). Data were expressed as mean ± standard deviation.

Conclusion

High asynchrony index and high ineffective trigger index may be early predictors of weaning failure in mechanically ventilated COPD patients.

Background

Patient-ventilator asynchrony is defined as a lack of organization between the patient and ventilator timing of both inspiration and expiration [1]. It is a commonly reported problem during mechanical ventilation. Thille et al. found that 24% of patients developed asynchrony in at least 10% of their breaths; moreover, they stated that the most frequent asynchronies were ineffective triggering and double triggering [2]. Eighty percent of chronic obstructive pulmonary disease (COPD) patients experienced ineffective triggering, where it is considered the most frequent asynchrony in this group of patients [3,4,5]. Asynchrony between patient and ventilator also leads to prolonged duration of invasive ventilation and increased possibility of weaning failure [6].

Both spread and intensity of asynchrony during the early phase of weaning in COPD patients have never satisfactorily been described. The aim of the current study was to describe the patient-ventilator asynchrony and its impact on weaning outcomes in mechanically ventilated COPD patients.

Methods

The current prospective observational cohort study was performed in respiratory intensive care unit (R.I.C.U), Chest Department, Assuit University Hospital. The study was performed during the period between February 2018 and August 2019; it involved 100 mechanically ventilated COPD patients. All patients recruited in this study were diagnosed with COPD according to the GOLD guideline criteria (based on history, physical examination, chest radiography, and previous pulmonary function tests if available). If not available once the patient became stable, spirometry was done to confirm the diagnosis [7]. The exclusion criteria included age < 18 years, tracheostomy, failure to trigger breaths even in cases of receiving neuromuscular blocking agents, encephalopathy which is not caused by hypercapnia or hypoxemia either post-arrest or due to cerebrovascular stroke, patients with unplanned weaning, and COPD patients where intubation is not related to exacerbation, e.g., acute pulmonary edema.

Baseline characteristics including age, gender, smoking history, history of the present illness, and the severity of illness were measured by Acute Physiology and Chronic Health Evaluation II (APACHE II) [8].

Arterial blood gasses were obtained on admission (named baseline) immediately before intubation, 24 h after intubation, during spontaneous breathing trial (SBT), 2 h after weaning, 24 h after weaning, and when there is a clinical demand. Clinical and ventilator data were recorded. The duration of sedation and also the duration of mechanical ventilation prior to inclusion in the study were determined.

Equipment utilized

All patients underwent mechanical ventilation using a Puritan Bennett 840 (Puritan Bennett, Pleasanton, CA). Patients underwent recording of pressure, flow, and volume waveforms for a period of 30 min. Ventilator settings were set by clinicians caring for the patient and were not modified during the 30-min observation period.

Patient-ventilator asynchrony

Patient-ventilator asynchrony is detected in 30-min sessions at 12, 24, 36, and 48 h following intubation. The asynchrony index by visual assessment of pressure, flow, and volume graphs is detected. Asynchrony index (AI) is calculated by dividing the number of asynchronies by the total respiratory rate (ventilator cycle + wasted effort) × 100. Ineffective trigger index (ITI) is calculated in the same way by dividing the number of ineffective triggers by the total respiratory rate (ventilator cycle + wasted effort) × 100 [2]. An AI of 10% or higher defined severe patient-ventilator asynchrony [2].

Type of asynchronies

Trigger asynchrony

Ineffective triggering or trigger asynchrony means ineffective effort where the ventilator is unable to detect patient effort. It is characterized by the inability to deliver ventilator breath despite the change in expiratory flow, or decline in the waveform of pressure/time [2].

Double triggering

Double triggering is characterized by two subsequent inspirations with short expiratory time, where the first cycle is being patient triggered [9, 10].

Auto-triggering

Auto-triggering means that breath is delivered from the ventilator without patient triggering. It is observed as a cycle that is delivered to the patient in the absence of a prior decrease in airway pressure [2].

Flow asynchrony

Flow asynchrony implies that the delivery of a mechanical breath is not suitable to the needs of the patient. One can observe the concave pressure-time airway curve of the assisted breath as a result of inadequate flow delivery; this means the flow provided by the mechanical breath is lower than the patient demand [11].

Cycle asynchrony

Premature cycle

The neural inspiratory time is longer than mechanical inspiratory time, and it is presented as a significant airway pressure decrease detected immediately following the end of the inspiratory phase [11].

Late cycle

The neural inspiratory time is shorter than the mechanical inspiratory time. It is characterized by an abrupt decrease in inspiratory flow in the flow/time curve and an increase in airway pressure near the end of the inspiratory phase [11].

Weaning from mechanical ventilation

Weaning trial was considered after patient stabilization. Patients underwent daily assessment of readiness to wean. Weaning was done according to the followed protocol in R.I.C.U [12] (using the spontaneous mode of weaning with low-pressure support (8 cm H2O) and zero PEEP with the same FIO2 (< 40%) for at least 2 h).

The study design was approved by the Scientific Ethics Committee of the Faculty of Medicine of Assiut University. After meeting the inclusion criteria, informed written consent was obtained from the surrogate decision-maker before enrollment.

Statistical analysis

Data analysis was done using SPSS (Statistical Package for Social Science for Windows statistical package, version 16.0) [13]. The results of different variables were presented as mean ± SD. The mean ± SD values were compared between the groups using Student’s t test or the Mann-Whitney test depending on whether the distribution deported from the normal. Logistic regression analysis was used to demonstrate the association of different variables to the failed group, expressed as the odds ratios (OR) and 95% confidence intervals (CI) for values showing statistical significance or tendency toward significance in Student’s t test. A p-value < 0.05 was considered statistically significant.

Results

A total of 100 mechanically ventilated COPD patients were enrolled in this study. Failed weaning was noticed in 27 (27%) patients while 73 (73%) patients had successful weaning as shown in Fig. 1. The main characteristics of the patients are indicated in Table 1. There were no significant differences between both groups with respect to age and sex. Smoking index was significantly higher among those with failed weaning (1400 (300–2400) vs. 800 (250–2000); P = 0.02). APACHE score was found to be significantly higher among those with failed weaning (29.01 ± 5.17 vs. 24.50 ± 4.19; P < 0.001). Regarding the duration of mechanical ventilation, it was significantly higher among those with failed weaning (9.70 ± 3.94 vs. 4.26 ± 1.23; P < 0.001). Clinical and ventilator data of the studied patients at the time of weaning showed significant differences between the two groups of patients where respiratory rate, peak pressure, rapid shallow breathing index, level of PEEP applied, and also the duration of sedation were higher among patients with failed weaning, whereas spontaneous tidal volume and static and dynamic compliance were higher among patients with successful weaning. Table 2 shows the patients’ asynchronies in the studied patients based on the outcomes of weaning. Patients with failed weaning had significantly higher ineffective trigger, double trigger, delayed trigger, and total asynchronies in comparison with those with successful weaning (P < 0.05). In particular, patients with failed weaning had significantly higher asynchrony index (A.I) and ineffective trigger index (ITI) in comparison with those with successful weaning (7.69 ± 3.71, 3.46 ± 2.59 versus 6.27 ± 3.14, 2.47 ± 2.08, respectively; P value 0.04) (Fig. 2). Both groups had insignificant auto-trigger, early cycle, and flow asynchrony (P > 0.05).

Fig. 1
figure 1

Weaning outcome in studied patients

Table 1 Baseline data of studied patients based on weaning outcome
Table 2 Patients’ asynchronies in studied patients based on the outcome of weaning
Fig. 2
figure 2

Asynchrony index and ineffective trigger index in studied patients based on the weaning outcome

Multivariate regression analysis showed that both ineffective trigger and total asynchronies were reliable predictors for failed weaning. At a cutoff of > 25, ineffective trigger had 56% sensitivity and 85% specificity with an area under the curve of 0.66 for the prediction of failed weaning. The total asynchronies had 77% sensitivity and 73% specificity with an area under the curve of 0.52 for the prediction of failed weaning at a cutoff of > 49 (Fig. 3).

Fig. 3
figure 3

Sensitivity and specificity of an ineffective trigger and total asynchrony on predicting weaning failure

Discussion

Librating the patient from endotracheal tube and mechanical ventilation with subsequent successful weaning is the main target since the time of initiating invasive mechanical ventilation. Several studies assessed patient-ventilator asynchrony during mechanical ventilation and its impact on the prolonged duration of mechanical ventilation [3, 5, 6]. The present study assesses the types of patient-ventilator asynchrony in COPD patients and their impact on weaning outcomes.

With respect to the baseline data of the studied patients, smoking index, APACHE II score, and duration of mechanical ventilation were significantly higher in failed weaning COPD patients compared to the successful weaning group. A higher smoking index may lead to more deterioration of pulmonary function, and increased disease severity and systemic inflammation. APACHE II score reflects the severity of illness of the primary disease and its effect on weaning outcomes. Several studies documented higher APACHE II scores in failed weaning patients [14, 15]. Also, longer duration of mechanical ventilation in the failed weaning group may reflect increased disease severity which is supported by the presence of a higher APACHE II score and more significant respiratory muscle weakness. The present study observed higher RSBI in failed weaning COPD patients; actually, several studies in COPD and non-COPD patients reported higher levels of RSBI in the failed group of patients, but they reported different cutoff values for RSBI [14, 16]. The most commonly reported cutoff value for RSBI was > 105, but as regards COPD because of the presence of ineffective respiratory effort with the subsequent failed triggering of ventilator leading to inaccurate assessment of RSBI [17]. Another study reported that RSBI < 80 predicts failed weaning in 56% of mechanically ventilated COPD patients [5]. Static and dynamic compliance were higher among patients with successful weaning in the current study. The changes in respiratory mechanics of COPD patients in the form of airway obstruction, hyperinflation, increased respiratory rate, and subsequent dynamic hyperinflation, all of these events direct the functional residual capacity to the flat portion of the P-V curve leading to increased work of breathing and decreased compliance [18]. Studies documented that the presence of COPD per se is a predictor of weaning failure [18, 19]. Ghiani et al. [20] supported the present study; they documented that patients with failed weaning had lower compliance and increased work of breathing.

With respect to the patient-ventilator asynchrony, the present study demonstrated that patients with failed weaning had significantly higher ineffective trigger, double trigger, delayed trigger, and total asynchronies in comparison with those with successful weaning (P < 0.05). In particular, patients with failed weaning had significantly higher asynchrony index (A.I) and ineffective trigger index (ITI). De Wit et al. [21] observed that ineffective trigger is frequently observed during mechanical ventilation, which participated in weaning failure, prolonged ICU stay, and morbidity. Also, several studies attributed asynchronies in ventilated COPD patients to abnormal respiratory mechanics, where patients with hyperinflation and intrinsic positive end-expiratory pressure PEEP had a higher prevalence of ineffective trigger [5, 22]. The present study demonstrated higher level of PEEP is needed in the failed weaning group which may be attributed to the presence of a higher level of auto-PEEP and hyperinflation in this group of patients. Grasso et al. and De Wit et al. [21, 23] also attributed ineffective triggering to sedation which impairs respiratory drive, the result which agrees with the present study where failed weaning patients had a significantly longer duration of sedation. Similarly, other studies demonstrated that all types of asynchrony are common in COPD patients, and they participated in mortality and length of hospital stay [24]. Multiple studies demonstrated that patients with ineffective trigger index and asynchrony index > 10% had longer duration of mechanical ventilation and ICU and hospital stay [25, 26].

Conclusion

Patient-ventilator asynchrony is a commonly encountered problem in mechanically ventilated COPD patients. High asynchrony index and high ineffective trigger index may be early predictors of weaning failure in these patients.

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

COPD:

Chronic obstructive pulmonary diseases

NIV:

Non-invasive ventilation

APACHE score:

Acute Physiologic Assessment and Chronic Health Evaluation score

PEEP:

Positive end-expiratory pressure

RSBI:

Rapid shallow breathing index

ITI:

Ineffective trigger index

AI:

Asynchrony index

References

  1. Beck J, Gottfried SB, Navalesi P, Skrobik Y, Comtois N, Rossini M, Sinderby C (2001) Electrical activity of the diaphragm during pressure support ventilation in acute respiratory failure. Am J Respir Crit Care Med 164(3):419–424. https://doi.org/10.1164/ajrccm.164.3.2009018

    Article  CAS  PubMed  Google Scholar 

  2. Thille AW, Rodriguez P, Cabello B, Lellouche F, Brochard L (2006) Patient-ventilator asynchrony during mechanical ventilation: prevalence and risk factors. Intensive Care Med 32(10):1515–1522. https://doi.org/10.1007/s00134-006-0301-8

    Article  PubMed  Google Scholar 

  3. Fabry B, Guttmann J, Eberhard L, Bauer T, Haberthür C, Wolff G (1995) An analysis of desynchronization between the spontaneously breathing patient and ventilator during inspiratory pressure support. Chest 107(5):1387–1394. https://doi.org/10.1378/chest.107.5.1387

    Article  CAS  PubMed  Google Scholar 

  4. Nava S, Bruschi C, Fracchia C, Braschi A, Rubini F (1997) Patient-ventilator interaction and inspiratory effort during pressure support ventilation in patients with different pathologies. Eur Respir J 10(1):177–183. https://doi.org/10.1183/09031936.97.10010177

    Article  CAS  PubMed  Google Scholar 

  5. Purro A, Appendini L, De Gaetano A, Gudjonsdottir M, Donner CF, Rossi A (2000) Physiologic determinants of ventilator dependence in long-term mechanically ventilated patients. Am J Respir Crit Care Med 161(4):1115–1123. https://doi.org/10.1164/ajrccm.161.4.9812160

    Article  CAS  PubMed  Google Scholar 

  6. Chao DC, Scheinhorn DJ, Stearn-Hassenpflug M (1997) Patient-ventilator trigger asynchrony in prolonged mechanical ventilation. Chest 112(6):1592–1599. https://doi.org/10.1378/chest.112.6.1592

    Article  CAS  PubMed  Google Scholar 

  7. Safka KA, Wald J, Wang H, McIvor L, McIvor A (2017) GOLD stage and treatment in COPD: a 500 patient point prevalence study. Chronic Obstr Pulm Dis 4(1):45–55

    Google Scholar 

  8. Knaus WA, Draper EA, Wagner DP, Zimmerman JE (1985) APACHE II: a severity of disease classification system. Crit Care Med 13(10):818–829. https://doi.org/10.1097/00003246-198510000-00009

    Article  CAS  PubMed  Google Scholar 

  9. Liao KM, Ou CY, Chen CW (2011) Classifying different types of double-triggering based on airway pressure and flow deflection in mechanically ventilated patients. Respir Care 56(4):460–466. https://doi.org/10.4187/respcare.00731

    Article  PubMed  Google Scholar 

  10. Murias G, Lucangelo U, Blanch L (2016) Patient-ventilator asynchrony. Curr Opin Crit Care 22(1):53–59. https://doi.org/10.1097/MCC.0000000000000270

    Article  PubMed  Google Scholar 

  11. Jolliet P, Tassaux D (2006) Clinical review: patient-ventilator interaction in chronic obstructive pulmonary disease. Crit Care 10(6):236

    Article  Google Scholar 

  12. Boles JM, Bion J, Connors A, Herridge M, Marsh B, Melot C, Pearl R, Silverman H, Stanchina M, Vieillard-Baron A, Welte T (2007) Weaning from mechanical ventilation. Eur Respir J 29(5):1033–1056. https://doi.org/10.1183/09031936.00010206

    Article  PubMed  Google Scholar 

  13. IBM_SPSS (2016) Statistical Package for Social Science. Ver.24. Standard version. Copyright© SPSS Inc., 2016, NY, USA

    Google Scholar 

  14. Goharani R, Vahedian-Azimi A, Galal IH, de Souza LC, Farzanegan B, Bashar FR, Vitacca M, Shojaei S, Mosavinasab SM, Takaki S, Miller AC (2019) A rapid shallow breathing index threshold of 85 best predicts extubation success in chronic obstructive pulmonary disease patients with hypercapnic respiratory failure. J Thorac Dis 11(4):1223–1230. https://doi.org/10.21037/jtd.2019.03.103

    Article  PubMed  PubMed Central  Google Scholar 

  15. Farghaly S, Hasan AA (2017) Diaphragm ultrasound as a new method to predict extubation outcome in mechanically ventilated patients. Aust Crit Care 30(1):37–43. https://doi.org/10.1016/j.aucc.2016.03.004

    Article  PubMed  Google Scholar 

  16. Karthika M, Al Enezi FA, Pillai LV, Arabi YM (2016) Rapid shallow breathing index. Ann Thorac Med 11(3):167–176. https://doi.org/10.4103/1817-1737.176876

    Article  PubMed  PubMed Central  Google Scholar 

  17. Boutou AK, Abatzidou F, Tryfon S, Nakou C, Pitsiou G, Argyropoulou P, Stanopoulos L (2011) Diagnostic accuracy of the rapid shallow breathing index to predict a successful spontaneous breathing trial outcome in mechanically ventilated patients with chronic obstructive pulmonary disease. Heart Lung 40(2):105–110. https://doi.org/10.1016/j.hrtlng.2010.02.002

    Article  PubMed  Google Scholar 

  18. Gea J, Agusti A, Roca J (2013) Pathophysiology of muscle dysfunction in COPD. J Appl Physiol 114(9):1222–1234. https://doi.org/10.1152/japplphysiol.00981.2012

    Article  CAS  PubMed  Google Scholar 

  19. Dasgupta A, Rice R, Mascha E, Litaker D, Stoller JK (1999) Four-year experience with a unit for long-term ventilation (respiratory special care unit) at the Cleveland Clinic Foundation. Chest. 116(2):447–455. https://doi.org/10.1378/chest.116.2.447

    Article  CAS  PubMed  Google Scholar 

  20. Ghiani A, Paderewska J, Sainis A, Crispin A, Walcher S, Neurohr C (2020) Variables predicting weaning outcome in prolonged mechanically ventilated tracheotomized patients: a retrospective study. J Intensive Care 8(1):19–23. https://doi.org/10.1186/s40560-020-00437-4

    Article  PubMed  PubMed Central  Google Scholar 

  21. De Wit M, Miller KB, Green DA, E Ostman H, Gennings C, Epstein S. (2009) Ineffective triggering predicts increased duration of mechanical ventilation. Crit Care Med 37(10):2740–2745. https://doi.org/10.1097/ccm.0b013e3181a98a05

    Article  PubMed  Google Scholar 

  22. Appendini L, Purro A, Patessio A, Zanaboni S, Carone M, Spada E, Donner CF, Rossi A (1996) Partitioning of inspiratory muscle workload and pressure assistance in ventilator-dependent COPD patients. Am J Respir Crit Care Med 154(5):1301–1309. https://doi.org/10.1164/ajrccm.154.5.8912740

    Article  CAS  PubMed  Google Scholar 

  23. Grasso S, Fanelli V, Cafarelli A, Dalfino L, Ingenito G, Ancona G (2004) Patient ventilator interaction during PSV at different levels of sedation in ALI patients. Intensive Care Med 30:S13–S13

    Google Scholar 

  24. Blanch L, Sales B, Montanya J, Lucangelo U, Garcia-Esquirol O, Villagra A, Chacon E, Estruga A, Borelli M, Burgueño MJ, Oliva JC, Fernandez R, Villar J, Kacmarek R, Murias G (2012) Validation of the Better Care system to detect ineffective efforts during expiration in mechanically ventilated patients: a pilot study. Intensive Care Med 38(5):772–780. https://doi.org/10.1007/s00134-012-2493-4

    Article  PubMed  Google Scholar 

  25. Blanch L, Villagra A, Sales B, Montanya J, Lucangelo U, Luján M et al (2015) Asynchronies during mechanical ventilation are associated with mortality. Intensive Care Med 14:633–641

    Article  Google Scholar 

  26. Thille AW, Rodriguez P, Cabello B, Lellouche F, Brochard L (2006) Patient-ventilator asynchrony during assisted mechanical ventilation. Intensive Care Med 32(10):1515–1522. https://doi.org/10.1007/s00134-006-0301-8

    Article  PubMed  Google Scholar 

Download references

Acknowledgements

The authors thank all workers in the respiratory ICU for their honest work and meticulous observation of patients.

Funding

There was no funding.

Author information

Authors and Affiliations

Authors

Contributions

MME selected the research and help in writing. SMA collected the patient’s data and participated in writing the manuscript. SHS and RME participated in the data analysis, statistics, writing, and publication. All authors have read and approved the final manuscript and ensure that this is the case.

Corresponding author

Correspondence to Samiaa H. Sadek.

Ethics declarations

Ethics approval and consent to participate

The study design was approved by the Scientific Ethics Committee of the Faculty of Medicine of Assiut University (IRB no 17200531, dated 5/5/2015). After meeting the inclusion criteria, informed written consent was obtained from the surrogate decision-maker before enrollment. Clinical trial number: NCT04735497

Consent for publication

Not applicable. There are no identifying images or other personal or clinical details of participants that compromise anonymity.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sadek, S.H., El-kholy, M.M., Abdulmoez, M.S. et al. Patient-ventilator asynchrony as a predictor of weaning failure in mechanically ventilated COPD patients. Egypt J Bronchol 15, 30 (2021). https://doi.org/10.1186/s43168-021-00076-9

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s43168-021-00076-9

Keywords