The diagnostic accuracy of an inclusive three-window ultrasonography assessment for the rapid authentication of endotracheal tube position in RICU

Abstract

Background

Assurance of proper endotracheal tube (ETT) location is crucial immediately after intubation as undiagnosed esophageal intubation can be catastrophic. The primary purpose for this study is to determine the diagnostic accuracy of to evaluate the accuracy of an inclusive three-window ultrasonography assessment for the rapid authentication of endotracheal tube position in the intensive care unit (RICU) with reference to Co2 monitors (capnography) (the gold standard technique), The study included 100 patients who needed emergency intubation in the ICU of Aswan university hospital. Upon entrance to ICU, intubations was done by the residents and collective bedside three-windows ultra-sonography (tracheal, lung, diaphragmatic ultra-sonography) was carried out instantly after intubation Subsequently, the correct position of the endotracheal tube was established by the resident investigator via the use a capnometer.

Results

Waveform capnography revealed endotracheal intubation in 80 cases (80%) and esophageal intubation in 20 cases (20%). However, trans-tracheal ultra-sonography (TUS) was able to detect endotracheal intubation in 78 cases (78%) and esophageal intubation in 22 cases (22%) patients. SLS detected only 17 esophageal intubations from 20 cases detected by CO2 detectors. DUS was able to detect proper endotracheal intubation in 77 cases (77%) and esophageal intubation in 23 cases (23%). However, it detected only 17 esophageal intubations from 20 cases detected by Co2 detectors.

Conclusions

Ultra-sonography, as recently introduced practice for validation of correct endotracheal tube location has both high accuracy and safety profile and can be used as a primary authentication technique.

Trial registration

NCT05747248

Introduction

Nowadays, endotracheal intubation is considered a fundamental management procedure during emergency resuscitation. Assurance of proper endotracheal tube (ETT) location is crucial immediately after intubation as undiagnosed esophageal intubation can be catastrophic. Moreover, there was a reported incidence of unrecognized ETT misplacement during endotracheal intubation, ranged from 2.9 to 16.7% and is a common cause of morbidity and mortality in emergency intubations [1].

Straight imagining of the ETT passing through the vocal cords can be virtually used, however it is not always promising, especially if laryngoscopy is challenging. The alternative methods of confirmation including (observation of chest rising after intubation and both lungs auscultation) are varying in their degree of accuracy. Nevertheless, over 50% of one lung intubations may proceed undiagnosed by chest auscultation [2].

Waveform capnography was approved as the gold standard technique for the fundamental realization of ETT position [3]. Recent guidelines recommended constant waveform Co2 monitoring in addition to clinical evaluation as the most accurate measures to confirm the accurate position of an endotracheal tube (ETT). However, end-tidal carbon dioxide (ETCo2) measurement requires a minimum of five “breathing cycles” for validation, which can lead to gastric insufflation and numerous complications if the ETT was falsely set in the esophagus, also capnography cannot discriminate between main tracheal and endobronchial placement of endotracheal tube [4]. Furthermore, quantifiable capnography, (the rationale for authorization of endotracheal intubation), is undependable in cardiac arrest patients [5].

Ultrasound is a simple, real-time, and less invasive diagnostic method that is commonly used in the ICU. A previous report demonstrated that ETT placement with ultrasound is more rapidly than the usual technique of auscultation and capnography and is as quick as lung auscultation alone [6].

The primary aim for this study was to evaluate the diagnostic validity of an inclusive three-window ultrasonography assessment for the rapid authentication of endotracheal tube position in the respiratory intensive care unit (RICU) with reference to Co2 monitors (capnography) (the gold standard technique). A secondary outcome was to estimate the elapsed time before validation of endotracheal tube location.

Patients and methods

This prospective observational study was carried out in the intensive care unit (ICU) of Aswan University Hospital during the period from December 2021 to October 2022.

Inclusions criteria

The study included 100 patients who required emergency intubation in the ICU of Aswan university hospital.

Exclusions criteria

Patients less than 18 years old, a strenuous intubation history, anatomical neck deformities, atypical airway anatomy, pleural pathologies, surgical emphysema, or lung disorders that might disturb the study technique were excluded from the study.

Procedure

Upon entrance to ICU, Intubations was done by the residents using a cuff endotracheal tube with a caliber from 7 to 7.5 mm and collective bedside ultra-sonography was carried out instantly after intubation by the investigator who was not concerned in the patients' care and not informed about the capnography results.

A SonoScape ultrasound (Model: A5, SonoScape (China) Co, Ltd.) was used for TUS, a 9–12 MHz linear probe was used. The probe was located transversely on the anterior neck entirely above the suprasternal notch promptly after intubation, and then the transducer was displaced to the left to assess whether the esophagus was empty or ETT inflated. The ETT was clarified as “endo-tracheal” if only a single hyperechoic air-mucosa (A-M) interface with a comet-tail artifact was noticed or “intra-esophageal” if an additional A-M interface (double-tract sign) (Figs. 1, 2 and 3).

Fig. 1
figure 1

Sonographic image of tracheal intubation

Fig. 2
figure 2

Sonographic image of esophageal intubation

Fig. 3
figure 3

Sliding lung sign

To detect SLS over both lungs, another 3.75 MHz curvilinear probe was placed horizontally on both sides, Images were taken within the 3th to 5th intercostal spaces, alongside the mid axillary line. A positive SLS implied lung expansion with ventilation. On the base of the presence or absence of the sliding lung sign on both sides of the chest, a distinction of endotracheal tube location was made, existence on both sides of the chest was presumed to indicate tracheal intubation. SLS existence on the right side only was assumed to claim right main stem bronchial intubation. Finally, non-existence of SLS on either side was acknowledged to denote esophageal intubation [7].

Diaphragm ultrasonography was done with the use of a 3.5-MHz curved probe, the probe was situated in the right upper quadrant of the abdomen, accurately below the edge of the ribs with a 45° angle toward the chest near the mid-clavicular line. The probe will toward the right side of the patient. During positive pressure via ventilation with bag (inspiratory phase), diaphragm motion toward the abdomen was registered as an intratracheal intubation. In contrast, the observation of diaphragm motion toward chest or non-significant motion was be in favor of esophageal intubation [8].

Subsequently, the correct location of the endotracheal tube was established by the resident investigator via the use a capnometer (Scio Four, Drager, Germany), a positive result of capnography was defined as the detection of exhaled CO2 (> 4 mm Hg) after at least five breathing cycles with a characteristic CO2 waveform as shown in Fig. 4. The interval from the end of the endotracheal tube insertion to the time when the investigator elucidated the sonographic results and to the time of appropriating the results of capnography were estimated. A data gathering sheet was marked down to document the patients’ demographics, capnography results, ultrasonography results, and the time passing to confirm tube position.

Fig. 4
figure 4

Normal capnogram waveform performed in this study

Statistical analysis

Date analysis were done using SPSS (Statistical Package for Social Science) software program version 25.0 (SPSS Inc., Chicago, IL, USA). P value considered statistically significant if < 0.05.

Results

Comparison of demographic and clinical characteristics of the study population according to capnography results into tracheal intubation group and esophageal intubation group was illustrated in Table 1. Endotracheal intubation was detected in 80 cases (80%), while esophageal intubation was detected in 20 cases (20%). There was no significant difference between the two groups as regard age, BMI, sex, and medical diagnosis (P value > 0.05) (Table 1).

Table 1 Comparison of demographic and clinical characteristics of the study population according to the capnography results

Table 2 showed the comparison of the transtracheal ultrasonography (TUS) results with the continuous capnography waveform results where waveform capnography detected endotracheal intubation in 80 cases (80%) and esophageal intubation in 20 cases (20%). However, tracheal ultrasonography was able to detect endotracheal intubation in 78 cases (78%) and esophageal intubation in 22 cases (22%) patients. TUS detected 18 esophageal intubations from 20 cases detected by CO2 detectors and 2 detected as positive (false positive), however it did not detect four out of 74 tracheal intubations detected by CO2 detectors (false negatives).

Table 2 Comparison of the transtracheal ultrasonography (TUS) results with the continuous capnography waveform results

Table 3 illustrate that ultra-sonographic SLS was able to detect proper endotracheal intubation in 78(78%), esophageal intubation in 22 cases (22%). However, SLS detected only 17 esophageal intubations from 20 cases detected by CO2 detectors and 3 cases detected as positive (false positive); however, it did not detect 5 out of 80 tracheal intubations detected by CO2 detectors (false negatives).

Table 3 Comparison of ultra-sonographic (SLS results) results with the continuous capnography waveform results

Table 4 demonstrated that comparison of the combined TUS and ultra-sonographic SLS results with the capnography results where the combined TUS and ultra-sonographic SLS results were able to detect proper endotracheal intubation in 84 cases (84%), esophageal intubation in 16 cases (22%). However, it detected only 15 esophageal intubations from 20 cases detected by CO2 detectors and 5 cases were detected as positive (false positive), however it did not detect one case out of 80 tracheal intubations detected by CO2 detectors (false negatives).

Table 4 A comparison of the combined TUS and ultra-sonographic SLS results with the capnography results

Table 5 demonstrated that comparison of DUS results with the capnography results where DUS was able to detect proper endotracheal intubation in 77 cases (77%), esophageal intubation in 23 cases (23%). However, it detected only 17 esophageal intubations from 20 cases detected by CO2 detectors and 3 cases were detected as positive (false positive), however it did not detect 6 cases out of 80 tracheal intubations detected by CO2 detectors (false negatives).

Table 5 A comparison of DUS results with the capnography results

Statistical calculations of the diagnostic test performance of TUS, SLS and DUS in the confirmation of ETT position were shown in Table 6. The combined TUS and SLS had the highest sensitivity while DUS had the lowest sensitivity, while TUS had the highest specificity and combined TUS and SLS had the lowest specificity.

Table 6 The diagnostic test performance of TUS, SLS, and DUS in the confirmation of ETT position

The comparison of the mean time used to confirm correct placement of endotracheal tube ETT by ultrasonography and capnography is demonstrated in Table 7. It was noticed that the mean time of ultrasonography was significantly shorter than the mean time of capnography (P value = 0.044).

Table 7 Comparison of the mean time used to confirm the correct position of endotracheal tube ETT by ultrasonography and capnography

Discussion

Currently endotracheal intubation is considered a fundamental management procedure during emergency resuscitation. Assurance of proper endotracheal tube (ETT) location is crucial immediately after intubation as undiagnosed esophageal intubation can be catastrophic. The primary purpose of this study was to determine the diagnostic validity of an inclusive three-window ultrasonography assessment for the rapid authentication of endotracheal tube position in the intensive care unit (RICU) with reference to Co2 monitors (capnography) (the gold standard technique). A secondary outcome was to determine the elapsed time before authentication of the accurate endotracheal tube position.

Our study showed that the comparison of (TUS) results with the continuous capnography waveform results where waveform capnography revealed endotracheal intubation in 80 cases (80%) and esophageal intubation in 20 cases (20%). However, TUS was able to detect endotracheal intubation in 78 cases (78%) and esophageal intubation in 22 cases (22%) patients. TUS distinguished 18 esophageal intubations from 20 cases detected by Co2 sensors and 2 noticed as positive (false positive); however, it did not detect four out of 74 tracheal intubations detected by Co2 detectors (false negatives). Concomitant with our results, Kabil et al. [9] on their study on forty cases disclosed that ultrasound detected tracheal intubation in 35 cases (97.22% of all patients with true tracheal intubation). Only one patient with tracheal intubation was detected by ultrasound as esophageal (2.78%). Moreover, all patients with esophageal intubation (n = 4) were appropriately detected by ultrasound as esophageal intubation. Similarly, Masoumi et al. [10] summarized that, from their total 100 cases, there was 93 cases (93%) had true positive results (tracheal intubation), and seven cases (7%) had true negative results (esophageal intubation). Out of which, 6 (85.7%) patients had negative waveform capnography reports, which was in favor of esophageal intubation, and the rest of them (n = 1; 14.3%) had undergone appropriate tracheal intubation based on positive waveform capnography.

We found that that direct localization of intubation by TUS had (95.0%) sensitivity, (90.0%) specificity, (97.4%) positive predictive value and (81.8%) negative predictive value to confirm the correct intubation with area under the curve was (0.925 and P < 0.001). In harmony with our results, Chen et al. [11] showed (75.0%) sensitivity, with (100%) specificity. Similarly, Fahmy and Kinawy [12], disclosed that the TUS use for authorization of ETT location showed sensitivity of)95.95%(, specificity of)83.33%(, PPV of)98.6%(, NPV of)62.5%(, and accuracy of (95%). Furthermore, Gottlieb et al. [13] results showed that the sensitivity and specificity of the static assessment technique in defining the ETT positions were [93.6% and 98.3%, correspondingly]. Chou et al. [14] pointed to the high efficacy of USG in the detection of esophageal intubation. In addition, it can be used as additional evidence with high sensitivity and specificity for the evaluation of the airway, definitely in many units where the capnometry is unavailable and, if obtainable, may be untrustworthy. Das and Choupoo [15], found that the mutual sensitivity and specificity of ultrasonography for recognition of appropriate ETT location were (98%, respectively). Sun et al. [16], found a closely excellent negative likelihood ratios in evaluating endotracheal tube location using TUS with the following results [the sensitivity (98.9%), specificity 100%, PPV (100%), and NPV (85.7%), correspondingly]. Adi et al. [17] found that there was a very good accordance between the bedside TUS and waveform capnography with their results [sensitivity (98%), specificity (100%), PPV (100%), and NPV (75.0%)]. Another study presented that TUS is a desirable and appreciated tool for the evaluation of appropriate endotracheal intubation, with a sensitivity (96.2%) and specificity (100%) with PPV and NPV [100 and 69.6%, correspondingly] [18].

Regarding SLS, we found that the ultrasonographic SLS was able to detect proper endotracheal intubation in 78 cases (78%), esophageal intubation in 22 cases (22%). However, SLS detected only 17 esophageal intubations from 20 cases detected by Co2 detectors and 3 cases detected as positive (false positive). In harmony with our results, Bernard, et al. [19] demonstrated that in 16 cases, the ultrasonographic lung‐sliding sign correctly identified lung intubation as confirmed with a flexible bronchoscope with one false‐positive). Similarly, Fahmy and Kinawy [12], summarized that the ultra-sonographic SLS was able to detect proper endotracheal intubation in 69 cases (86.3%), esophageal intubation in 6 cases (7.5%) and right main stem bronchial intubation in 5 cases (6.2%) cases. SLS correctly detected all six esophageal intubations; however, its presence on the right side and absence on the left was noticed in 5 cases out of 74 tracheal intubations (false negatives) denoted right main stem intubation and ETT was taken out till positive lung sliding gained bilaterally. Furthermore, they demonstrated that SLS accurately identified esophageal placement, but was less accurate in identifying tracheal intubation compared to capnography.

We found that the sensitivity of SLS is (93.8%) while, specificity is (85%) and the AUC is (0.90) which is highly accurate. In accordance with our results, Amin et al. [20] disclosed that the use of pleural USG for confirmation of ETT placement in their study showed sensitivity of 89.5%, specificity of 50.0%, PPV of 97.1% NPV of 20.0%, and accuracy of 87.5%. Correspondingly, Fahmy and Kinawy [12], summarized that the use of pleural USG for confirmation of ETT placement in their study showed sensitivity of 93.24%, specificity of 100%, PPV of 100% NPV of 54.5%, and accuracy of 93.75%, and overall accuracy was 93.75%. Álvarez-díaz et al. [21] confirmed that the sensitivity of the ultrasound was 98.6%, specificity was 52.9%. Furthermore, Sim et al. [22] in their study have described that the global validity of ultra-sonographic SLS for authenticating ETT location during emergent intubation was (88.7%).

We found that the combined TUS and ultra-sonographic SLS results were able to detect proper endotracheal intubation in 84 cases (84%), esophageal intubation in 16 cases (22%). However, it detected only 15 esophageal intubations from 20 cases detected by CO2 detectors and 5 cases were detected as positive (false positive); however, it did not detect one case out of 80 tracheal intubations detected by CO2 detectors (false negatives). Furthermore, regarding the diagnostic test performance of the combined TUS and SLS in the confirmation of ETT position, we found that the sensitivity is 98.8% however, specificity is 75%, and the AUC is 0.90 which is highly accurate. In harmony with our results, Fahmy and Kinawy [12], found that on combining TUS and SLS, the sensitivity and negative predictive values raised to 100% and the diagnostic accuracy rise to (98.75%). Moreover, Rahul et al. [23] found that the diagnostic accuracy of the US method was 100% (20/20) and that of the standard method 95% (19/20), with a p value of 1.0. The sensitivity and PPV of the US method was 100% (CI 79.9–100%), and the standard method had a 100% (CI 79.1–100%) sensitivity and 95% (CI 73.1–99.7%) PPV.

Regarding diaphragmatic ultrasonography, we found that DUS was able to detect proper endotracheal intubation in 77 cases (77%), esophageal intubation in 23 cases (23%). However, it detected only 17 esophageal intubations from 20 cases detected by Co2 detectors and 3 cases were detected as positive (false positive), however it did not detect 6 cases out of 80 tracheal intubations detected by Co2 detectors (false negatives), Furthermore, we summarized that that indirect localization of the tube by diaphragmatic U/S had 92.5% sensitivity and 85.0% specificity to confirm the correct intubation with area under the curve was 0.921 and P < 0.001. This result was concomitant with Hosseini et al. [8] who found that diaphragm Ultrasound appropriately identified 11 out of 12 esophageal intubations with a sensitivity of [92%] (95% CI = 62–100) but misidentified one esophageal intubation as tracheal.

It was noticed that the mean time of ultrasonography was considerably shorter than the mean time of capnography (P value = 0.044). In accordance, Fahmy and Kinawy [12], found that the total ultrasonography time was substantially less than that of capnography (P < 0.001) and the mean variance was 5 s in favor of ultrasound. Similarly, Lahham, et al. [24] summarized that three-window POCUS (tracheal, lung and diaphragmatic ultrasonography) was accomplished on average 25 min faster than plain chest X-rays (95% CI 6.2–43.9 min, P = 0.005).

Our study had several limitations: first, its small sample size which was not representative to the whole population. Moreover, we did not sufficiently investigate esophageal intubations due to small number of esophageal intubations detected by our study. Second, ultrasonography is acknowledged to be operator dependable procedure. Finally, TUS may not be feasible for each intubation challenge. The existence of a huge neck swellings, abnormal upper airway anatomy, soft tissue air, or substantial neck edema can make imaging more difficult to detect ETT location. To ascertain our study results, Additional studies must be guided with multiple investigators and patient assortment must be planned as successively to decline selection bias.

Conclusions

Endotracheal intubation (EI) is a crucial technique in airway management. It is important to verify the correct location and depth of insertion of ETT after each intubation attempt to avoid serious complications. Ultra-sonography, as recently introduced practice for validation of correct endotracheal tube location has both high accuracy and safety profile and can be used as a primary authentication technique.

Availability of data and materials

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

Abbreviations

ETT:

Endotracheal tube

RICU:

Respiratory intensive care unit

TUS:

Trans tracheal ultrasonography

SLS:

Sliding lung sign

DUS:

Diaphragmatic motion ultrasonography

ETCO2:

End-tidal carbon dioxide

BMI:

Body mass index

USG:

Ultrasonography

ETI:

Endotracheal intubation

References

  1. Russotto V, Cortegiani A, Raineri SM, Gregoretti C, Giarratano A (2017) Respiratory support techniques to avoid desaturation in critically ill patients requiring endotracheal intubation: a systematic review and meta-analysis. J Crit Care 1(41):98–106

    Article  Google Scholar 

  2. Sitzwohl C, Langheinrich A, Schober A, Krafft P, Sessler DI, Herkner H, Gonano C, Weinstabl C, Kettner SC (2010) Endobronchial intubation detected by insertion depth of endotracheal tube, bilateral auscultation, or observation of chest movements: randomised trial. BMJ 9:341

    Google Scholar 

  3. Thomas VK, Paul C, Rajeev PC, Palatty BU (2017) Reliability of ultrasonography in confirming endotracheal tube placement in an emergency setting. Indian J Crit Care Med 21(5):257

    Article  PubMed  PubMed Central  Google Scholar 

  4. Link MS, Berkow LC, Kudenchuk PJ, Halperin HR, Hess EP, Moitra VK, Neumar RW, O’Neil BJ, Paxton JH, Silvers SM, White RD (2015) Part 7: adult advanced cardiovascular life support: 2015 American Heart Association guidelines update for cardiopulmonary resuscitation and emergency cardiovascular care. Circulation. 132(18_suppl_2):S444-64

    Article  PubMed  Google Scholar 

  5. Karacabey S, Sanri E, Gencer EG, Guneysel O (2016) Tracheal ultrasonography and ultrasonographic lung sliding for confirming endotracheal tube placement: Speed and Reliability. Am J Emerg Med 34:953–6

    Article  PubMed  Google Scholar 

  6. Abbasi S, Farsi D, Zare MA, Hajimohammadi M, Rezai M, Hafezimoghadam P (2015) Direct ultrasound methods: a confirmatory technique for proper endotracheal intubation in the emergency department. Eur J Emerg Med 22(1):10–16

    Article  PubMed  Google Scholar 

  7. Weaver B, Lyon M, Blaivas M (2006) Confirmation of endotracheal tube placement after intubation using the ultrasound sliding lung sign. Acad Emerg Med 13(3):239–244

    Article  PubMed  Google Scholar 

  8. Hosseini JS, Talebian MT, Ghafari MH, Eslami V (2013) Secondary confirmation of endotracheal tube position by diaphragm motion in right subcostal ultrasound view. Int J Crit Illn Inj Sci 3(2):113

    Article  PubMed  PubMed Central  Google Scholar 

  9. Kabil AE, Ewis AM, Al-Ashkar AM, Abdelatif MA, Nour MO (2018) Real-time tracheal ultrasonography for confirming endotracheal tube placement. Egypt J Bronchol 12(3):323–328

    Article  Google Scholar 

  10. Masoumi B, Azizkhani R, Emam GH, Asgarzadeh M, Kharazi BZ (2017) Predictive value of tracheal rapid ultrasound exam performed in the emergency department for verification of tracheal intubation. Open Access Maced J Med Sci 5(5):618

    Article  PubMed  PubMed Central  Google Scholar 

  11. Chen W, Chen J, Wang H, Chen Y (2020) Application of bedside real-time tracheal ultrasonography for confirmation of emergency endotracheal intubation in patients in the intensive care unit. J Int Med Res 48(4):0300060519894771

    Article  PubMed  Google Scholar 

  12. Fahmy H, Kinawy S (2019) Value of integrated tracheal and lung sliding ultrasonography for affirmation of proper endotracheal tube placement in patients undergoing intubation for general anesthesia. J Anesth Clin Res 10(908):2

    Google Scholar 

  13. Gottlieb M, Nakitende D, Sundaram T, Serici A, Shah S, Bailitz J (2018) Comparison of static versus dynamic ultrasound for the detection of endotracheal intubation. West J Emerg Med 19(2):412

    Article  PubMed  PubMed Central  Google Scholar 

  14. Chou EH, Dickman E, Tsou PY, Tessaro M, Tsai YM, Ma MH, Lee CC, Marshall J (2015) Ultrasonography for confirmation of endotracheal tube placement: a systematic review and meta-analysis. Resuscitation 1(90):97–103

    Article  Google Scholar 

  15. Das SK, Choupoo NS, Haldar R, Lahkar A (2015) Transtracheal ultrasound for verification of endotracheal tube placement: a systematic review and meta-analysis. Can J Anesth 62(4):413–423

    Article  PubMed  Google Scholar 

  16. Sun JT, Chou HC, Sim SS, Chong KM, Ma MH, Wang HP, Lien WC (2014) Ultrasonography for proper endotracheal tube placement confirmation in out-of-hospital cardiac arrest patients: two-center experience. J Med Ultrasound 22(2):83–87

    Article  Google Scholar 

  17. Adi O, Chuan TW, Rishya M (2013) A feasibility study on bedside upper airway ultrasonography compared to waveform capnography for verifying endotracheal tube location after intubation. Crit Ultrasound J 5(1):1–1

    Article  Google Scholar 

  18. Shebl E, Said AM (2019) The role of tracheal ultrasonography in confirming endotracheal tube placement in respiratory intensive-care unit patients. Egypt J Chest Dis Tuberc 68(3):351

    Google Scholar 

  19. Bernard N, Ender J, Turton E (2018) The use of lung-ultrasound to confirm correct placement of left sided double lumen tubes. J Cardiothorac Vasc Anesth 1(32):S97–S98

    Article  Google Scholar 

  20. Amin MA, Abdelraouf HS, Ahmed AH (2021) Comparative study between tracheal ultrasound and pleural ultrasound for confirmation of endotracheal tube position. Sci J Al-Azhar Med Facult Girls 5(1):217

    Google Scholar 

  21. Álvarez-Díaz N, Amador-García I, Fuentes-Hernández M, Dorta-Guerra R (2015) Comparison between transthoracic lung ultrasound and a clinical method in confirming the position of double-lumen tube in thoracic anesthesia A pilot study. Rev Esp Anestesiol Reanim (Engl Ed). 62(6):305–12

    Article  Google Scholar 

  22. Sim SS, Lien WC, Chou HC, Chong KM, Liu SH, Wang CH, Chen SY, Hsu CY, Yen ZS, Chang WT, Huang CH (2012) Ultrasonographic lung sliding sign in confirming proper endotracheal intubation during emergency intubation. Resuscitation 83(3):307–312

    Article  PubMed  Google Scholar 

  23. Rahul K, Cara K, Ahmad A (2016) Using ultrasound to confirm endotracheal tube position in the Intensive Care Unit. J Anesth Intensive Care Med 1:555560

    Google Scholar 

  24. Lahham S, Wilson SP, Turner E, Subeh M, Rosen MA, Youssefian A, Anderson CL, Hosseini M, Rosen S, Gari A, Fox JC (2018) Three-window ultrasonography confirmation of endotracheal tube placement. Res Cardiovasc Med 7(4):192

    Article  Google Scholar 

Download references

Acknowledgements

None.

Funding

No financial support was needed.

Author information

Authors and Affiliations

Authors

Contributions

IGS was the principal investigator, formulated the idea, and wrote the first draft of discussion. MA collected the data, formulated the results, and edited the final draft and revision. SS was responsible for methodology and statistical analysis. The manuscript has been read and approved by all the authors.

Corresponding author

Correspondence to Islam G. Sayed.

Ethics declarations

Ethics approval and consent to participate

The Research Ethics Committee at the Faculty of Medicine, Aswan University, has approved the study (IRB number: 425/12/19) and all patients provided written informed consent before participation.

Consent for publication

The manuscript has been read and approved by all the authors.

Competing interests

The authors declare that they have no competing interests.

Additional information

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Sayed, I.G., Salama, S. & Abdallah, M. The diagnostic accuracy of an inclusive three-window ultrasonography assessment for the rapid authentication of endotracheal tube position in RICU. Egypt J Bronchol 17, 16 (2023). https://doi.org/10.1186/s43168-023-00190-w

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s43168-023-00190-w

Keywords